A Fishkeeping forum. FishKeepingBanter.com

If this is your first visit, be sure to check out the FAQ by clicking the link above. You may have to register before you can post: click the register link above to proceed. To start viewing messages, select the forum that you want to visit from the selection below.

Go Back   Home » FishKeepingBanter.com forum » ponds » General
Site Map Home Authors List Search Today's Posts Mark Forums Read Web Partners

Wish me luck



 
 
Thread Tools Display Modes
  #1  
Old August 7th 04, 04:30 PM
gng
external usenet poster
 
Posts: n/a
Default Wish me luck

Today I attempt to install a new Sequence 7200 pump on my 2500 gallon pond.
Will keep you posted and post some pics when done. Keep your fingers
crossed that Murphy's Law is broken today.....

Gary


  #2  
Old August 7th 04, 08:41 PM
~ jan JJsPond.us
external usenet poster
 
Posts: n/a
Default Wish me luck

Wishes, and good vibes, sent your way! ~ jan )

Today I attempt to install a new Sequence 7200 pump on my 2500 gallon pond.
Will keep you posted and post some pics when done. Keep your fingers
crossed that Murphy's Law is broken today.....

Gary


~Power to the Porg, Flow On!~
  #3  
Old August 8th 04, 07:13 AM
gng
external usenet poster
 
Posts: n/a
Default Wish me luck

It works - though I would like a bit more flow. The pond is fitted with
1.5" tubing. Would upgrading to 2" make a difference?
"~ jan JJsPond.us" wrote in message
...
Wishes, and good vibes, sent your way! ~ jan )

Today I attempt to install a new Sequence 7200 pump on my 2500 gallon

pond.
Will keep you posted and post some pics when done. Keep your fingers
crossed that Murphy's Law is broken today.....

Gary


~Power to the Porg, Flow On!~



  #4  
Old August 8th 04, 05:49 PM
chagoi
external usenet poster
 
Posts: n/a
Default Wish me luck

gng wrote:

It works - though I would like a bit more flow. The pond is fitted with
1.5" tubing. Would upgrading to 2" make a difference?
"~ jan JJsPond.us" wrote in message
...

Wishes, and good vibes, sent your way! ~ jan )


Today I attempt to install a new Sequence 7200 pump on my 2500 gallon


pond.

Will keep you posted and post some pics when done. Keep your fingers
crossed that Murphy's Law is broken today.....

Gary


~Power to the Porg, Flow On!~




larger pipe = less restriction = more flow

I know this is for PVC, but it shows the relationship between different
sizes



Table1: Saturation Flow Rates for Schedule 40 PVC
Pipe Size Approximate Saturation Flow Rate
1 inch 25 GPM 1500 GPH
1 ½ inch 60 GPM 3600 GPH
2 inch 150 GPM 9000 GPH


Table 2: Maximum Recommended Flow Rates And Pump Sizes
for Various Pipe Sizes
Pipe Size Max Pump Size Approx. Flow Rate with Max Pump Size
1 inch 1/3 hp 15 GPM 900 GPH
1 ¼ inch ½ hp 25 GPM 2100 GPH
1 ½ inch ½ hp 45 GPM 2700 GPH
2 inch 1 hp 75 GPM 4500 GPH
2 ½ inch 1 ½ hp 110 GPM 6600 GPH
3 inch 2 hp 200 GPM 12000 GPH




-- Bigger is better, and less is more
/\/\ike
Chagoi
http://ourkoipond.com
  #5  
Old August 8th 04, 05:58 PM
chagoi
external usenet poster
 
Posts: n/a
Default Wish me luck

chagoi wrote:


larger pipe = less restriction = more flow

I know this is for PVC, but it shows the relationship between different
sizes



Table1: Saturation Flow Rates for Schedule 40 PVC
Pipe Size Approximate Saturation Flow Rate
1 inch 25 GPM 1500 GPH
1 ½ inch 60 GPM 3600 GPH
2 inch 150 GPM 9000 GPH


Table 2: Maximum Recommended Flow Rates And Pump Sizes
for Various Pipe Sizes
Pipe Size Max Pump Size Approx. Flow Rate with Max Pump Size
1 inch 1/3 hp 15 GPM 900 GPH
1 ¼ inch ½ hp 25 GPM 2100 GPH
1 ½ inch ½ hp 45 GPM 2700 GPH
2 inch 1 hp 75 GPM 4500 GPH
2 ½ inch 1 ½ hp 110 GPM 6600 GPH
3 inch 2 hp 200 GPM 12000 GPH




-- Bigger is better, and less is more
/\/\ike
Chagoi
http://ourkoipond.com



try this for tables 1 & 2
http://ourkoipond.com/psafr.htm

--
/\/\ike
Chagoi
http://ourkoipond.com
  #6  
Old August 8th 04, 06:50 PM
gng
external usenet poster
 
Posts: n/a
Default Wish me luck

Thanks - it actually looks pretty good right now since the filter was
cleaned. But it looks as if I should change out the 1.5" to 2" if I want a
bigger waterfall. From what I can see, it looks pretty significant. Anyone
out there change out pipe size and notice a big difference? There are some
areas where it must stay 1.5", such as the pipe that is cemented into the
waterfall. Will this negate me changing out the rest of the pipe? Is the
flow only as good as the smallest pipe size?

"chagoi" wrote in message
...
chagoi wrote:


larger pipe = less restriction = more flow

I know this is for PVC, but it shows the relationship between different
sizes



Table1: Saturation Flow Rates for Schedule 40 PVC
Pipe Size Approximate Saturation Flow Rate
1 inch 25 GPM 1500 GPH
1 ½ inch 60 GPM 3600 GPH
2 inch 150 GPM 9000 GPH


Table 2: Maximum Recommended Flow Rates And Pump Sizes
for Various Pipe Sizes
Pipe Size Max Pump Size Approx. Flow Rate with Max Pump Size
1 inch 1/3 hp 15 GPM 900 GPH
1 ¼ inch ½ hp 25 GPM 2100 GPH
1 ½ inch ½ hp 45 GPM 2700 GPH
2 inch 1 hp 75 GPM 4500 GPH
2 ½ inch 1 ½ hp 110 GPM 6600 GPH
3 inch 2 hp 200 GPM 12000 GPH




-- Bigger is better, and less is more
/\/\ike
Chagoi
http://ourkoipond.com



try this for tables 1 & 2
http://ourkoipond.com/psafr.htm

--
/\/\ike
Chagoi
http://ourkoipond.com



  #7  
Old August 9th 04, 02:29 AM
RichToyBox
external usenet poster
 
Posts: n/a
Default Wish me luck

Based on the flow rating of the Sequence 7200, the friction loss for 1.5
inch pipe would be about 50 foot of head per hundred foot of pipe, which
means the pump is not capable of getting that flow. For 2 inch pipe the
head loss is about 11 feet, and that is reasonable. For the 1.5 inch pipe,
the flow is probably about 1/2 what it is capable of.

--
RichToyBox
http://www.geocities.com/richtoybox/index.html
"gng" wrote in message
...
Thanks - it actually looks pretty good right now since the filter was
cleaned. But it looks as if I should change out the 1.5" to 2" if I want

a
bigger waterfall. From what I can see, it looks pretty significant.

Anyone
out there change out pipe size and notice a big difference? There are

some
areas where it must stay 1.5", such as the pipe that is cemented into the
waterfall. Will this negate me changing out the rest of the pipe? Is the
flow only as good as the smallest pipe size?

"chagoi" wrote in message
...
chagoi wrote:


larger pipe = less restriction = more flow

I know this is for PVC, but it shows the relationship between

different
sizes



Table1: Saturation Flow Rates for Schedule 40 PVC
Pipe Size Approximate Saturation Flow Rate
1 inch 25 GPM 1500 GPH
1 ½ inch 60 GPM 3600 GPH
2 inch 150 GPM 9000 GPH


Table 2: Maximum Recommended Flow Rates And Pump Sizes
for Various Pipe Sizes
Pipe Size Max Pump Size Approx. Flow Rate with Max Pump

Size
1 inch 1/3 hp 15 GPM 900 GPH
1 ¼ inch ½ hp 25 GPM 2100 GPH
1 ½ inch ½ hp 45 GPM 2700 GPH
2 inch 1 hp 75 GPM 4500 GPH
2 ½ inch 1 ½ hp 110 GPM 6600 GPH
3 inch 2 hp 200 GPM 12000 GPH




-- Bigger is better, and less is more
/\/\ike
Chagoi
http://ourkoipond.com



try this for tables 1 & 2
http://ourkoipond.com/psafr.htm

--
/\/\ike
Chagoi
http://ourkoipond.com





  #8  
Old August 9th 04, 03:56 PM
gng
external usenet poster
 
Posts: n/a
Default Wish me luck

Thanks - so the big question is whether it would make any difference at all
if I changed out the input feed tubing with 2" but left the output (to
filter, uv, and waterfall) 1.5". Right now the waterfall is looking great -
should I just forget about it?

"RichToyBox" wrote in message
news:gsARc.227496$%_6.203565@attbi_s01...
Based on the flow rating of the Sequence 7200, the friction loss for 1.5
inch pipe would be about 50 foot of head per hundred foot of pipe, which
means the pump is not capable of getting that flow. For 2 inch pipe the
head loss is about 11 feet, and that is reasonable. For the 1.5 inch

pipe,
the flow is probably about 1/2 what it is capable of.

--
RichToyBox
http://www.geocities.com/richtoybox/index.html
"gng" wrote in message
...
Thanks - it actually looks pretty good right now since the filter was
cleaned. But it looks as if I should change out the 1.5" to 2" if I

want
a
bigger waterfall. From what I can see, it looks pretty significant.

Anyone
out there change out pipe size and notice a big difference? There are

some
areas where it must stay 1.5", such as the pipe that is cemented into

the
waterfall. Will this negate me changing out the rest of the pipe? Is

the
flow only as good as the smallest pipe size?

"chagoi" wrote in message
...
chagoi wrote:


larger pipe = less restriction = more flow

I know this is for PVC, but it shows the relationship between

different
sizes



Table1: Saturation Flow Rates for Schedule 40 PVC
Pipe Size Approximate Saturation Flow Rate
1 inch 25 GPM 1500 GPH
1 ½ inch 60 GPM 3600 GPH
2 inch 150 GPM 9000 GPH


Table 2: Maximum Recommended Flow Rates And Pump Sizes
for Various Pipe Sizes
Pipe Size Max Pump Size Approx. Flow Rate with Max Pump

Size
1 inch 1/3 hp 15 GPM 900 GPH
1 ¼ inch ½ hp 25 GPM 2100 GPH
1 ½ inch ½ hp 45 GPM 2700 GPH
2 inch 1 hp 75 GPM 4500 GPH
2 ½ inch 1 ½ hp 110 GPM 6600 GPH
3 inch 2 hp 200 GPM 12000 GPH




-- Bigger is better, and less is more
/\/\ike
Chagoi
http://ourkoipond.com


try this for tables 1 & 2
http://ourkoipond.com/psafr.htm

--
/\/\ike
Chagoi
http://ourkoipond.com







  #9  
Old August 9th 04, 04:06 PM
chagoi
external usenet poster
 
Posts: n/a
Default Wish me luck

I does make a difference on the suction side also.
i.e.

If you get your self a coffee stir, and a soda straw, and try to suck
you soda (pop to all you non-Pennsylvanians) through both of them you
will find it harder to suck it through the smaller straw.

So it is with a pump,
the smaller the suction piping the more the pump has to work, thus less
flow.

The smaller the discharge piping the harder the pump has to work. Thus
less flow but more pressure.

--
/\/\ike
Chagoi
http://ourkoipond.com

gng wrote:

Thanks - so the big question is whether it would make any difference at all
if I changed out the input feed tubing with 2" but left the output (to
filter, uv, and waterfall) 1.5". Right now the waterfall is looking great -
should I just forget about it?


  #10  
Old August 10th 04, 01:55 AM
RichToyBox
external usenet poster
 
Posts: n/a
Default Wish me luck

Changing the input side will do more to increase flow than changing out the
output side, making water available to the pump. A restricted input will
cause the pump to cavitate and wear prematurely. If you are happy with the
current flow, then you do not have to increase the discharge pipe size, but
by changing it you would at least double the flow.

--
RichToyBox
http://www.geocities.com/richtoybox/index.html
"gng" wrote in message
...
Thanks - so the big question is whether it would make any difference at

all
if I changed out the input feed tubing with 2" but left the output (to
filter, uv, and waterfall) 1.5". Right now the waterfall is looking

great -
should I just forget about it?

"RichToyBox" wrote in message
news:gsARc.227496$%_6.203565@attbi_s01...
Based on the flow rating of the Sequence 7200, the friction loss for 1.5
inch pipe would be about 50 foot of head per hundred foot of pipe, which
means the pump is not capable of getting that flow. For 2 inch pipe the
head loss is about 11 feet, and that is reasonable. For the 1.5 inch

pipe,
the flow is probably about 1/2 what it is capable of.

--
RichToyBox
http://www.geocities.com/richtoybox/index.html
"gng" wrote in message
...
Thanks - it actually looks pretty good right now since the filter was
cleaned. But it looks as if I should change out the 1.5" to 2" if I

want
a
bigger waterfall. From what I can see, it looks pretty significant.

Anyone
out there change out pipe size and notice a big difference? There are

some
areas where it must stay 1.5", such as the pipe that is cemented into

the
waterfall. Will this negate me changing out the rest of the pipe? Is

the
flow only as good as the smallest pipe size?

"chagoi" wrote in message
...
chagoi wrote:


larger pipe = less restriction = more flow

I know this is for PVC, but it shows the relationship between

different
sizes



Table1: Saturation Flow Rates for Schedule 40 PVC
Pipe Size Approximate Saturation Flow Rate
1 inch 25 GPM 1500 GPH
1 ½ inch 60 GPM 3600 GPH
2 inch 150 GPM 9000 GPH


Table 2: Maximum Recommended Flow Rates And Pump Sizes
for Various Pipe Sizes
Pipe Size Max Pump Size Approx. Flow Rate with Max Pump

Size
1 inch 1/3 hp 15 GPM 900 GPH
1 ¼ inch ½ hp 25 GPM 2100 GPH
1 ½ inch ½ hp 45 GPM 2700 GPH
2 inch 1 hp 75 GPM 4500 GPH
2 ½ inch 1 ½ hp 110 GPM 6600 GPH
3 inch 2 hp 200 GPM 12000 GPH




-- Bigger is better, and less is more
/\/\ike
Chagoi
http://ourkoipond.com


try this for tables 1 & 2
http://ourkoipond.com/psafr.htm

--
/\/\ike
Chagoi
http://ourkoipond.com








 




Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump

Similar Threads
Thread Thread Starter Forum Replies Last Post
Wish me Luck! pixi General 2 June 26th 04 10:54 PM
Beginner luck ? seed lover General 16 April 22nd 04 06:08 AM
Talk about bad luck, two leaks in two years Dan J.S. General 1 November 27th 03 02:51 AM
Luck with Eustralis Stellata Ryan Wilson Plants 2 July 10th 03 02:24 PM


All times are GMT +1. The time now is 05:26 AM.


Powered by vBulletin® Version 3.6.4
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 FishKeepingBanter.com.
The comments are property of their posters.