SalahiAndSon
external usenet poster
 
Posts: n/a
Default Pump head question

When you see a pump head rateing is this for output length only or both
input and output length combined? Iwaki pumps are rated at a specific gph at
a 4' head. I have 3.5' from the sump to the pump and 4' on the output side
to my tank. is this considered a 7.5' head or does the head rateing only
apply to the output side? Could someone please explain this or maybe point
me to a site or equation to make it simple. Any advice would be greatly
appreciated.
thanks
G.


  #2  
Old November 7th 04, 07:25 PM
Mort
external usenet poster
 
Posts: n/a
Default

Are you saying the pump is located
3.5' ABOVE The sump?





  #3  
Old November 7th 04, 08:01 PM
SalahiAndSon
external usenet poster
 
Posts: n/a
Default

I want it to be but i am curious if this is even possible? closer to about
2.5' above and 1' to the side.

G.


"Mort" wrote in message
. com...
Are you saying the pump is located
3.5' ABOVE The sump?







  #4  
Old November 7th 04, 08:06 PM
Billy
external usenet poster
 
Posts: n/a
Default


"SalahiAndSon" wrote in message
...
|I want it to be but i am curious if this is even possible? closer to
about
| 2.5' above and 1' to the side.
|


The pump, afaik, must be below the input water level or you'll not be
able to get the pump primed, and the danger of the pump running dry
if you DO get it primed, is high. Pumps that run dry do not have long
to live. May I ask WHY you want to do something like this? I'm sure
we can find a more realistic option for you....


  #5  
Old November 8th 04, 09:42 AM
pausto
external usenet poster
 
Posts: n/a
Default

SalahiAndSon wrote:

When you see a pump head rateing is this for output length only or both
input and output length combined? Iwaki pumps are rated at a specific gph at
a 4' head. I have 3.5' from the sump to the pump and 4' on the output side
to my tank. is this considered a 7.5' head or does the head rateing only
apply to the output side? Could someone please explain this or maybe point
me to a site or equation to make it simple. Any advice would be greatly
appreciated.
thanks
G.


Head, applies to the return line (line from pump to tank). It is
the vertical distance the pump must lift the water.
If the opening if the return line is submerged below the tank water
surface, then the vertical distance is measured from the surface of
the water in the sump to the surface of the water in the tank
(measured straight up and down vertically). If the return line
discharges above the tank surface, vertical measure from the sump
water surface to the top rim of the tank should be sufficient for
comparison to the pump flow chart.
The chart on the pump box typically does not account for flow
losses due to fittings (elbows, spray bar and such) and friction loss
of the hose.
http://www.aquatext.com/tables/frict-wat.htm
shows some scary looking calculations for friction loss, but the
easiest way to overcome losses is by using over sized hose and "long
sweep" fittings.

HTH
Paul
  #6  
Old November 10th 04, 10:17 PM
SalahiAndSon
external usenet poster
 
Posts: n/a
Default

First of all let me say thanks to all the ppl who responded to this post.
this is my first setup and I got a lot of friendly info. I went ahead and
put the pump at sump lvl with a 6' head but it is still pumping at an
acceptable gph and my tank is working great.
thanks again.
G.

"SalahiAndSon" wrote in message
...
When you see a pump head rateing is this for output length only or both
input and output length combined? Iwaki pumps are rated at a specific gph

at
a 4' head. I have 3.5' from the sump to the pump and 4' on the output side
to my tank. is this considered a 7.5' head or does the head rateing only
apply to the output side? Could someone please explain this or maybe point
me to a site or equation to make it simple. Any advice would be greatly
appreciated.
thanks
G.




 




Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump

Similar Threads
Thread Thread Starter Forum Replies Last Post
Main Pump is Dead Again - Question with Drilling 55GAL Sump reefdvr Reefs 3 June 26th 04 08:43 AM
Main Pump is Dead Again - Question with Drilling 55GAL Sump reefdvr Reefs 1 June 26th 04 01:56 AM
filter and pump question Cheryl General 12 May 1st 04 07:50 PM
Pump to a head Kevin Russell General 1 October 30th 03 11:23 PM
Pump Question infoseeker General 1 July 15th 03 08:26 AM


All times are GMT +1. The time now is 03:58 PM.


Powered by vBulletin® Version 3.6.4
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 FishKeepingBanter.com.
The comments are property of their posters.